Interactive Product Selector

Avanti grouts have been used around the world to stop leaks in and around concrete structures via crack injection, curtain grouting, probe-grouting, and tube-a-manchette grouting. The following interactive chart refers to Avanti grouts that have successfully been used for hazardous waste encapsulation, the prevention of structural movement due to ground water, as well as the sealing of entire sewer systems (mainlines, laterals, manholes) and underground transit systems.

For applications of a more Geotechnical nature related to controlling groundwater (reducing permeability to lower than 10-8 m/s for example) please call Avanti directly.

The following interactive decision chart has been designed to help you make decisions regarding the appropriate product for your particular waterproofing application. As you select answers to your quesitons, proceed until you reach a final answer. Because every project is unique, please call Avanti at 800-877-2570 for more specific assistance.


No Question/Heading Answers
1 Does the area experience wet/dry cycles or consistent moisture?
  • Wet/Dry
  • Consistent Moisture
2 Is it suitable for manned entry?
  • Yes
  • No
3 Is it suitable for manned entry?
  • Yes
  • No
4 Do you have multiple leaks or isolated leaks?
  • Multiple
  • Isolated
5 Suggested Action/Information
Probe Grouting with AV-278 (with catalyst AV-279). Typically needed: Airless paint sprayer pump (Graco 495 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To see animation click HERE.
6 Do you have multiple leaks or isolated leaks?
  • Multiple
  • Isolated
7 Using Acrylic or Urethane Grout?
  • Acrylic
  • Urethane or Not Sure
8 Is the wall/structure above or below grade (ground level)?
  • Above
  • Below
9 Is the wall/structure above or below grade (ground level)?
  • Above
  • Below
10 Using Acrylic or Urethane Grout?
  • Acrylic
  • Urethane or Not Sure
11 High water flow or low water flow?
  • High
  • Low
12 Suggested Action/Information:
Probe Grouting with AV-100 or AV-118. Typically needed: AV-101 and either AV-102 or AV-103, Proper PPE, probe(s) for delivering grout to desired depth. Dual component pump, storage tanks, & other equipment must be stainless steel or plastic. To see animation click HERE.
13 Do you have a dual component or single component pump?
  • Single
  • Dual
14 Suggested Action/Information
V-PAT Technique: Depending on the width of the crack, use AV-248 (with catalyst AV-249) for wider cracks, or AV-248-LV (with catalyst AV-249-LV) for thinner cracks. Typically needed: Airless paint sprayer (Graco 495 or similar), resin injectors (EZ-1s or similar), hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To see animation click HERE.
15 Suggested Action/Information
Curtain Grouting with AV-278 (with catalyst AV-279), or AV-280 (with catalyst AV-281). Typically needed: Airless paint sprayer pump (Graco 495 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To see animation click HERE.
16 Choose: Manual (EGP) Method or Injection Method
  • Manual (EGP)
  • Injection
17 High water flow or low water flow?
  • High
  • Low
18 Suggested Action/Information
Curtain Grouting with AV-278 (with catalyst AV-279), or AV-280 (with catalyst AV-281). Typically needed: Airless paint sprayer pump (Graco 495 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To see animation click HERE.
19 Will you use a pump (recommended) or a cartridge?
  • Pump
  • Cartridge
20 Suggested Action/Information
Crack Injection with flexible hydrophobic cartridge. (If using a hydrophilic cartridge in a dry area, shave off the excess foam and use surface sealant or coating.) Typically needed: resin cartridges, dual component gun, hammer drill, Proper PPE. To see animation click HERE.
21 Suggested Action/Information
V-PAT Technique: Depending on the width of the crack, use AV-248 (with catalyst AV-249) for wider cracks, or AV-248-LV (with catalyst AV-249-LV) for thinner cracks. Typically needed: Airless paint sprayer (Graco 495 or similar), resin injectors (EZ-1s or similar), hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To see animation click HERE.
22 Suggested Action/Information Contractor tips: Each project is unique. Call Avanti for ideas on how to slow high flow situations before you begin grouting.
Curtain Grouting with AV-278 (with catalyst AV-279), AV-280 (with catalyst AV-281) or AV-290 (AV-290 requires a dual component pump and static mixing nozzle). Typically needed: Airless paint sprayer pump (Graco 495 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To see animation click HERE.
23 Choose: Manual (EGP) Method or Injection Method
  • Manual (EGP)
  • Injection
24 Suggested Action/Information
The crack/joint must be wide enough to pack with "rope." EGP Method using AV-248 (with catalyst AV-249). Typically needed: Oakum or Resin Rod, Jiffy Mixer, Proper PPE. To open EGP Brochure click HERE. To see animation click HERE.
25 Will you use a pump (recommended) or a cartridge?
  • Pump
  • Cartridge
26
V-PAT Technique: Depending on the width of the crack, use AV-248 (with catalyst AV-249) for wider cracks, or AV-248-LV (with catalyst AV-249-LV) for thinner cracks. Typically needed: Airless paint sprayer (Graco 495 or similar), resin injectors (EZ-1s or similar), hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To see animation click HERE.
27 Do you want a flexible foam to fill the crack or a rigid foam on the back of the structure?
  • Flexible
  • Rigid
28 Suggested Action/Information
Crack Injection with AV-288 Hydroflex flexible hydrophobic cartridge. (If using a hydrophilic cartridge in a dry area, shave off the excess foam and use surface sealant or coating.) Typically needed: resin cartridges, dual component gun, hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To see animation click HERE.
29 Suggested Action/Information
Inject AV-290 resin into the soil with rigid hydrophobic cartridge. Typically needed: resin cartridges, single component gun, hammer drill, Proper PPE. To see Curtain Grouting video click HERE.
30 Suggested Action/Information
Curtain Grouting with AV-100 or AV-118. Typically needed: AV-101 and either AV-102 or AV-103, Proper PPE, probe(s) for delivering grout to desired depth. Dual component pump, storage tanks, & other equipment must be stainless steel or plastic. To see animation click HERE.
31 Do you have a dual component or single component pump?
  • Dual
  • Single
32 Suggested Action/Information
Curtain Grouting with AV-254 or AV-350. Typically needed: Dual component pump, AV-208 Technical-Grade Acetone, AV-284 Pump Wash. To see Curtain Grouting animation click HERE.
33 Suggested Action/Information
Curtain Grouting with AV-278 (with catalyst AV-279), or AV-280 (with catalyst AV-281). Typically needed: Airless paint sprayer pump (Graco 495 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To see Curtain Grouting animation click HERE.
34 Contractor tips: Each project is unique. Call Avanti for ideas on how to slow high flow situations before you begin grouting.Do you have a dual component or single component pump?
  • Dual
  • Single
35 Choose: Manual (EGP) Method or Injection Method
  • Manual (EGP)
  • Injection
36 Suggested Action/Information
Curtain Grouting with AV-254 or AV-350. Typically needed: Dual component pump, AV-208 Technical-Grade Acetone, AV-284 Pump Wash. To see Curtain Grouting animation click HERE.
37 Suggested Action/Information
Curtain Grouting with AV-278 (with catalyst AV-279), or AV-280 (with catalyst AV-281). Typically needed: Airless paint sprayer pump (Graco 495 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To see animation click HERE.
38 Suggested Action/Information
The crack/joint must be wide enough to pack with "rope." EGP Method using AV-202. Typically needed: Oakum or Resin Rod, Proper PPE. To open EGP Brochure click HERE. To see animation click HERE.
39 Will you use a pump (recommended) or a cartridge?
  • Pump
  • Cartridge
40 Suggested Action/Information
V-PAT Technique: Thick cracks (AV-202*); Medium Cracks (AV-333*, AV-330*, AV-202-LV), Thin Cracks (AV-315). * = Certified for use with potable water. Typically needed: Airless paint sprayer (Graco 495 or similar), resin injectors (EZ-1s or similar), hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To see animation click HERE.
41 Do you want a flexible foam to fill the crack or a rigid foam on the back of the structure?
  • Pump
  • Cartridge
42 Suggested Action/Information
Crack Injection with flexible hydrophilic cartridge. Thick cracks (AV-202*); Medium Cracks (AV-333*, AV-330*, AV-202-LV), Thin Cracks (AV-315). * = Certified for use with potable water. Typically needed: resin cartridges, single component gun, hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To see animation click HERE..
43 Suggested Action/Information
Inject AV-290 resin into the soil with rigid hydrophobic cartridge. Typically needed: resin cartridges, single component gun, hammer drill, Proper PPE. To see video click HERE.
44 Suggested Action/Information
Curtain Grouting with AV-254 or AV-350. Typically needed: Dual component pump, AV-208 Technical-Grade Acetone, AV-284 Pump Wash. To see Curtain Grouting animation click HERE.
45 Suggested Action/Information
Probe Grouting with AV-278 (with catalyst AV-279), or AV-275 (with catalyst AV-276). You will need: Airless paint sprayer pump (Graco 495 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To see Curtain Grouting animation click HERE.
What's Current
AvantiGrout is ON.
As seen on Fox Business News, CNBC, and Bloomberg TV.
21st Century News Video
Join Our Email List
Email:  
For Email Marketing you can trust


Avanti International
822 Bay Star Blvd.
Webster, TX 77598
281.486.5600 Phone
281.486.7300 Fax
800.877.2570 Toll-Free