The accelerator can be used in the grout or water side by following the chart below. |
|
| |
 |
|
AV-350/Water 1:8. The calculations in the tables below are estimates. Field conditions will vary widely; temperature variations and chemicals in the water can cause drastic variation from the figures below. This chart should only be used as a guideline.
Temperature: 24°C (75°F)
% Accelerator |
Amount in oz.’s |
Initial Reaction Time |
End Time |
0
1
2
4 |
6.4
12.8
25.6
|
0'40"
0'32"
0'30"
0'27" |
1'35"
1'25"
1'07"
1'05" |
Temperature: 13.5 °C (56°F)
% Accelerator |
Amount in oz.’s |
Initial Reaction Time |
End Time |
0
1
2
4 |
6.4
12.8
25.6
|
1'10"
0'35"
0'30"
0'27" |
2'15"
1'35"
1'30"
1'05" |
Temperature: 5°C (41°F)
% Accelerator |
Amount in oz.’s |
Initial Reaction Time |
End Time |
0
1
2
4 |
6.4
12.8
25.6
|
1'45"
1'15"
1'00"
0'40" |
3'35"
2'30"
2'10"
1'35"
|
|
|
| |
 |
|
Store in a dry area between 40°F and 80°F. |
|
| |
 |
|
 |
(Requires Acrobat Reader ) |
|
| |
 |
|
AV-350 contains Toluene Diisocyanate (TDI). When used in conjunction with AV-351, product should be used only in well ventilated areas in order to keep the vapor concentration low. A self-contained breathing apparatus should be worn in confined spaces where there is little ventilation and vapors are likely to be high. |
|
| |
 |
|
Immediately flush eyes with water for 15 minutes. Get immediate medical attention.
Wash affected area with soap and water. Remove contaminated clothing.
Remove to fresh air. If breathing is difficult, get medical attention.
Drink 2 glasses of water. Call a physician.
Never give anything by mouth to an unconscious or convulsing person.
|
|
| |
 |
|
The data, information and statements contained herein are believed to be reliable, but are not construed as a warranty or representation for which Avanti International assumes any legal responsibility. Since field conditions vary widely, users must undertake sufficient verification and testing to determine the suitability of any product or process mentioned in this or any other written material from Avanti for their own particular use. NO WARRANTY OF SUITABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE. In no case shall Avanti International be liable for consequential, special, or indirect damages resulting from the use or handling of this product.
|
|
| |
| |