| |
 |
|
 |
|
MDI-based, expansive material that reacts very rapidly to fill large voids and annular spaces. Cures to a resilient, rigid closed-cell foam. Nonflammable. Withstands wet/dry cycles.
|
|
| |
 |
|
Appearance:
Viscosity:
Specific Gravity:
% Solids:
Odor:
Flash Point:
|
Amber liquid
950 cps
1.12
100
Pungent aroma
425° F (218°) |
|
|
|
| |
 |
| |
Elongation:
Tensile Strength:
Shear Strength:
Water Absorption:
Shrinkage: |
44-50%
29.30 psi
17.10 psi
<1% (change in weight)
<1% |
ASTM D-1623
ASTM D-1623
ASTM C-2733
ASTM D-2127
ASTM D-2126 |
|
|
| |
 |
|
Slowly pour the pint of AV-281 Hydrocel catalyst into the 5-gallon pail of AV-280-12 Hydrofoam while slowly stirring for 3 to 5 minutes. The ideal temperature for mixing catalyst is between 65°F and 85°F. Do not allow moisture to penetrate the mixing pail. For faster set times add more AV-281 Hydrocel.
|
|
| |
 |
|
Store AV-280-12 Hydrofoam and AV-281 Hydrocel between 60°-85°F (16°-30°C). This product is packaged under dry nitrogen to extend shelf life.
|
|
| |
 |
| |
 |
(Requires Acrobat Reader ) |
|
| |
 |
|
Product should be used only in well ventilated areas in order to keep the vapor concentration low. Eye contact and repeated skin contact should be avoided. Normal protective clothing such as gloves and goggles are recommended. A self-contained breathing apparatus should be worn in confined spaces where there is little ventilation and vapors are likely to be high.
|
|
| |
 |
|
Eyes: Immediately flush eyes with water for 15 minutes. Get immediate medical attention.
Skin: Wash affected area with soap and water. Remove contaminated clothing.
Inhalation: Remove to fresh air. If breathing is difficult, get medical attention.
Ingestion: Drink 2 glasses of water. Call a physician.
Note: Never give anything by mouth to an unconscious or convulsing person. |
|
| |
 |
|
The data, information and statements contained herein are believed to be reliable, but are not construed as a warranty or representation for which Avanti International assumes any legal responsibility. Since field conditions vary widely, users must undertake sufficient verification and testing to determine the suitability of any product or process mentioned in this or any other written material from Avanti for their own particular use. NO WARRANTY OF SUITABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE. In no case shall Avanti International be liable for consequential, special, or indirect damages resulting from the use or handling of this product.
|
|
| |
| |